R407C Refrigerator EVI Heat Pump , Green 81.2KW EVI Air To Water Heater
Product Details:
Place of Origin: | China |
Brand Name: | Power World |
Certification: | CE,IEC,EC,ETL,CETL,C-TICK,WATER MARK,STANDARD MARK,SABS,SANS,SAA |
Model Number: | MG-200KFLW |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 PCS |
---|---|
Price: | negotiation |
Packaging Details: | Plywood packing |
Delivery Time: | 15-20 working days after received payment |
Payment Terms: | Western Union, L/C, D/A, T/T, MoneyGram, D/P |
Supply Ability: | 9,000pcs per month |
Detail Information |
|||
Application: | Hot Water,heating And Cooling | Color: | White,gold,Grey |
---|---|---|---|
Size: | 2000*1100*2080 | Packaging: | Plywood CTN |
Refrigerant: | R407C | Power Supply: | 380V/50HZ |
COP: | 3.79 | Highest/Rated Water Temperature (℃): | 60/55 |
EVI Condenser: | Plate-type | Working Ambient Temperature (℃): | -25 To 43 |
High Light: | Split Air Source Heat Pump,Air Source hot water Heat Pump |
Product Description
-25℃ Working 81.2KW EVI Air To Water Heater For Super Cold Region In EU With Galvanized Shell, Green R407C Refrigerator
Specifications of EVI Air To Water Heater For Super Cold Region In EU:
Model No. |
#MG-030A -KFLW |
#MG-030B -KFLW |
#MG-050- KFLW |
#MG-100 -KFLW |
#MG-200 -KFLW |
|
20℃ |
Heating Capacity(KW) |
10.8 |
11.8 |
20.6 |
40.6 |
81.2 |
Heating Input Power(KW) |
2.81 |
3.1 |
5.4 |
10.7 |
21.4 |
|
Rated Current(A) |
12.4 |
6.2 |
9 |
17.6 |
35.2 |
|
COP(Coefficient of Performance) |
3.84 |
3.81 |
3.81 |
3.79 |
3.79 |
|
Water Capacity(L/H) |
232 |
254 |
443 |
873 |
1745 |
|
-10℃ |
Heating Capacity(KW) |
6.3 |
7 |
12.6 |
24.4 |
48.8 |
Heating Input Power(KW) |
2.58 |
2.9 |
5.1 |
9.9 |
19.8 |
|
COP |
2.44 |
2.41 |
2.47 |
2.46 |
2.46 |
|
Water Capacity(L/H) |
135 |
150 |
271 |
524 |
1049 |
|
-20℃ |
Heating Capacity(KW) |
4.9 |
5.4 |
10.3 |
19.6 |
39.2 |
Heating Input Power(KW) |
2.45 |
2.68 |
5.05 |
9.8 |
19.6 |
|
COP |
2.00 |
2.01 |
2.04 |
2.00 |
2.00 |
|
Water Capacity(L/H) |
105 |
116 |
221 |
421 |
843 |
|
Voltage |
220V/50Hz |
380V/50Hz |
380V/50Hz |
380V/50Hz |
380V/50Hz |
|
Advised Cable |
3*2.5mm2 |
3*2.5mm2+2*1.5mm2 |
3*4mm2+2*2.5mm2 |
3*6mm2+ 2*2.5mm2 |
3*10mm2+ 2*4mm2 |
|
IP Grade(Level of protection) |
IPX4 |
IPX4 |
IPX4 |
IPX4 |
IPX4 |
|
Electric Shock Proof Grade |
I |
I |
I |
I |
I |
|
Working Condition (℃) |
-25 to 43 |
-25 to 43 |
-25 to 43 |
-25 to 43 |
-25 to 43 |
|
Rated Water Temp. Output(℃) |
55 |
55 |
55 |
55 |
55 |
|
Max Water Temp. Output(℃) |
60 |
60 |
60 |
60 |
60 |
|
Pipe Size(mm) |
DN25 |
DN25 |
DN25 |
DN32 |
DN65 |
|
Compressor |
Copeland |
Copeland |
Copeland |
Copeland |
Copeland |
|
EVI Exchanger |
Plate-type Heat Exchanger |
Plate-type Heat Exchanger |
Plate-type Heat Exchanger |
Plate-type Heat Exchanger |
Plate-type Heat Exchanger |
|
Thermostatic Expansion Valve |
Danfoss |
Danfoss |
Danfoss |
Danfoss |
Danfoss |
|
Air Flow |
Side Fan |
Side Fan |
Side Fans |
Top Fans |
Top Fans |
|
Refrigerator |
R407C |
R407C |
R407C |
R407C |
R407C |
|
Noise (dB(A)) |
≤55 |
≤55 |
≤58 |
≤66 |
≤66 |
|
Net Size(W*D*H)mm |
830*490*1160 |
830*490*1160 |
1110*490*1260 |
1580*800*1600 |
2000*1100*2080 |
|
N.W./G.W.(KG) |
100/106 |
100/106 |
145/155 |
298/313 |
585/645 |
|
Payment: 50% T/T in advance + 50% balance before shipment.(100% T/T for Sample/Try Order) |
||||||
After-sales Service & Quality warranty: 7 years for compressor, 1 years for whole unit. |
||||||
Sampletime: 7-45 days. |
||||||
Leadtime: 30 days after deposited & sample approval. |
||||||
Remarks: Offer 1% spare parts for container order only and this offer is valid within 30 days. |
Description of EVI Air To Water Heater For Super Cold Region In EU:
1.Environmental friendly and safe
Electric parts and water system is completely cut off, ensuring security water use, no pollution to the atmosphere and free of greenhouse effect and it is the safest water heater
2. Wide climatic zone adaptability
Our heat pumps with special designing possess better climatic adaptability, can work from -25℃ to 43℃.
3. Energy-saving
Heat pump water heater is a high efficient transferring heating equipment which is driven by electricity. The operating cost is only 1/4 of electric water heater, 1/3 of gas water heater.
4. Automatic intelligent control system
Adopting intelligent computerized automatic control system, no manual cost, easy to operate, convenient, make heat pump work safely and reliably.
Control panel with modularized unit design can control more flexible heat pumps packs, with user-friendly operating system interface, easy to operate..
5. Advanced testing methods
Adopting world-class Enthalpy potential laboratory to test heat pumps, except basic testing items, we also test heat pump in the ambient of temperature of -30℃ to test our heat pump performance.
6. Widely used
Heat pump is applied to hot water for household and commercial use like families, schools, hospitals, shower center, swimming pools, etc. and industrial use like electroplating, drying, etc.
Application of EVI Air To Water Heater For Super Cold Region In EU:
Business Organizations |
supermarket, large-scale shopping malls, exclusive agency, chain shops, large-scale sales, star-rated hotels, restaurants, travel agencies, pharmacy. |
Financial Organizations |
Banks, negotiable securities, funds, insurance companies, pawnshops; |
Public Places |
subway, airports, stations, gas stations, toll stations, bookstores, parks, exhibition halls, stadiums, museums, convention centers, ticket agencies, HR market, lottery centers; Real Estate Property: Apartments, villas, offices, commercial buildings, model rooms, property brokers; |
Entertainments |
Movie theaters, fitness halls, country clubs, clubs, massage rooms, bars, cafes, Internet bars, beauty shops, golf course |
Competitive Advantages of EVI Air To Water Heater For Super Cold Region In EU:
1.EVI technology:
Adopting the most advanced low temp Enhanced Vapors Injection compressor technology which can help heat pump work steadily even at temperature of -25℃.
2.Wide range of temperature:
EVI heat pump can work from -25℃.to 43℃. Widely used in different environment.
3. Higher heating capacity:
Using enlarging evaporator extracting more heat energy from air will increase COP.
4.Automatic start-up anti-freezing protection
When the ambient is below zero degree, the unit is in standby mode more than 30 minutes, Automatic anti-freezing device will be started up so that the unit will be protecting in lower temperature.
Welcome to visit our EVI Air To Water Heater For Super Cold Region In EU!